Wiring diagram of plc controlling a 24v solenoid valve via a relay the figure below is a wiring diagram of plc controlling a 24v solenoid valve with a 24v relay.
Plc relay wiring diagram. The output of the motor starter goes to a three phase ac motor. Plc and scada training courses. Here we will emulate the exact same high pressure alarm circuit using an allen bradley micrologix 1000 plc instead of a relay coil. Next all three phases are supplied to a motor starter that contains three contacts m and three thermal overload relays breakers.
The wire number changes across the relay contact to 06b. Figure 1 a motor controller schematic. Electrical wiring diagrams of a plc panel. Plc wiring diagrams guide include the discrete signals wiring plc digital input modules wiring plc output modules wiring and basics of plc terminations.
Note that these diagrams are without a barrier or isolator fuses and surge protector for keeping it very simple and understandable. The below list shows the basic types of wiring connections available for di do ai ao signals. The contacts m will be controlled by the coil m. These symbols are standard and will be discussed in chapter 24 both of the switches are powered by the hot output of the 24vac power supply.
This is less than the switch s trip setting of 50 psi leaving the switch in its normal closed. Digital input di signals. Wiring diagram of switches and relays to the plc plc wiring 3 5 in the example there are two inputs one is a normally open push button and the second is a temperature switch or thermal relay. Wiring diagrams of plc and dcs systems.
It shall be noted that if the plc adopts the transistor output com of the output point shall be connected to the 0v.